IIW V2 Calibration Block
IIW V2 Calibration Block

IIW V2 Calibration Block

MOQ : 1 Piece

IIW V2 Calibration Block Specification

  • Max Height
  • 63 mm
  • Mounting Type
  • Portable
  • Test Range
  • Calibration Block Standard Ranges
  • Application
  • Ultrasonic Flaw Detection Equipment Calibration
  • Equipment Type
  • Calibration Block
  • Automation Grade
  • Manual
  • Features
  • Precision Ground, Engraved Markings, Reference Standards
  • Hardness
  • ~170-210 HB (Steel)
  • Usage
  • Non-destructive Testing (NDT), Calibration
  • Control Mode
  • Manual
  • Edge Details
  • Beveled and Engraved for Visual Reference
  • Reference Holes
  • Diameter 3 mm and 1.5 mm
  • Workmanship
  • Precision Machined and Ground
  • Width
  • 63 mm
  • Storage Case
  • Supplied with Carry Case
  • Length
  • 150 mm
  • Block Type
  • IIW V2 Calibration Block
  • Material
  • High Quality Steel
  • Slot Dimensions
  • 22 mm x 1.2 mm
  • Shape
  • Rectangular with Slots and Holes
  • Marking
  • Laser Engraved Identification Number
  • Surface Finish
  • Highly Polished
  • Thickness
  • 25 mm
  • Standard Conformance
  • IIW V2, EN 12223, ISO 2400, BS 2704, ASTM E164
 

IIW V2 Calibration Block Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 5000 Pieces Per Month
  • Delivery Time
  • 10 Days
  • Main Domestic Market
  • All India
 

About IIW V2 Calibration Block



Discover a stellar deal on the IIW V2 Calibration Block-now available with a reduced price and superb savings! Crafted from masterful, high-quality steel, this rectangular calibration block perfectly aligns with global standards including IIW V2, EN 12223, ISO 2400, BS 2704, and ASTM E164. Its highly polished surface, precision ground finish, and laser engraved identification ensure exceptional accuracy for ultrasonic flaw detection calibration. This hot deal includes a secure carrying case, making it an ideal pick for professionals demanding reliability, portability, and brilliant performance in non-destructive testing. Don't miss this price cut for excellence!

Material Features & Applications of IIW V2 Calibration Block

Manufactured from high-quality steel with a hardness range of 170-210 HB, the IIW V2 Calibration Block is precision machined and ground for stellar accuracy. Its rectangular design incorporates slots, reference holes, and laser-engraved markings, all contributing to masterful flaw detection calibration in ultrasonic testing. This calibration block is a superb choice for NDT professionals, ensuring conformance to international standards. Designed for manual calibration, it reliably serves in laboratories, industrial plants, and testing facilities requiring meticulous measurements.


Payment, Delivery, and Packaging Overview

Experience handover simplicity and peace of mind with our lowest price guarantee. Our IIW V2 Calibration Block comes carefully packed in a robust carry case, ensuring safe arrival and easy portability. Catering to customers throughout India, we streamline the payment process with a variety of convenient terms designed to suit your needs. Upon confirmation, prompt dispatch and secure packaging ensure swift, worry-free delivery so your equipment is operational without delay.


FAQ's of IIW V2 Calibration Block:


Q: How is the IIW V2 Calibration Block used in ultrasonic flaw detection equipment calibration?

A: The block is used as a reference standard to calibrate ultrasonic testing devices, ensuring the accurate detection of flaws within materials by matching the instrument's readings against known dimensions and features.

Q: What materials and features set this calibration block apart?

A: Constructed from high-quality steel, the block features a highly polished surface, beveled edges, precision-ground slots and holes, as well as clear laser-engraved markings for optimal accuracy and durability.

Q: When will I receive the IIW V2 Calibration Block after purchase?

A: After order confirmation, the block is securely packaged and dispatched for prompt arrival. Delivery timelines may vary depending on shipping location within India, but we strive for the fastest handover possible.

Q: Where can this calibration block be applied?

A: This superb block is suited for laboratories, industrial facilities, and any setting requiring non-destructive testing (NDT) for calibration of ultrasonic flaw detection equipment.

Q: What benefits does the supplied carry case offer?

A: The robust storage case protects the calibration block during transport and storage, ensuring it remains in pristine condition and ready for immediate use on-site.

Q: What specifications does the IIW V2 Calibration Block meet?

A: It conforms to international standards such as IIW V2, EN 12223, ISO 2400, BS 2704, and ASTM E164, making it compatible with a wide range of ultrasonic testing equipment globally.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Calibration Block Category

Panel Mount Bhel Test Calibration Block

Panel Mount Bhel Test Calibration Block

Minimum Order Quantity : 1 Piece

Automation Grade : Manual

Mounting Type : Panel Mount

Equipment Type : Panel Mount Calibration Block

Max Height : 25 mm

Usage : Instrument Calibration

10 Step Carbon Steel Calibration Block

10 Step Carbon Steel Calibration Block

Minimum Order Quantity : 1 Piece

Automation Grade : Manual

Mounting Type : Handheld/Bench

Equipment Type : Ultrasonic Calibration Block

Max Height : 10 mm (Step Height)

Usage : Calibration of ultrasonic

MPI Yoke Calibration Block

MPI Yoke Calibration Block

Minimum Order Quantity : 1 Piece

Automation Grade : Manual

Mounting Type : Free standing or handheld

Equipment Type : MPI Yoke Calibration Block

Max Height : 13 mm

Usage : Magnetic Particle Inspection equipment calibration

Aluminium Test Block For Sensitivity

Aluminium Test Block For Sensitivity

Minimum Order Quantity : 1 Piece

Automation Grade : Manual

Mounting Type : Portable

Equipment Type : Test Block

Max Height : 10mm

Usage : Calibration and Sensitivity Verification



Back to top